Home
Hoeve De Vries · Unit GZ-041
Farmer
Online
Evaporator
Evaporating
Since 14:32 · 2h 14m
Scrubber
Washing
Since 13:55 · 2h 51m
Active Alerts2 active
Evaporator pH out of range
Evaporator12 min ago
Washer dry bobber triggered
Washer1h 3m ago
Last batch completed Today at 11:05
Process Detail
Evaporating Washing
Evaporator Timer
00:21:47
EvaporatorTime
Duration
60:00
Scrubber Timer
00:08:12
WasherFill
Duration
60:00
Sensor Readings tap to analyse
Evaporator pH
9.4pH
↓ 0.3 in 10 min
Washer pH
6.8pH
→ stable
Flow Rate
342l/h
→ stable
Commands
Evaporator
Buffer Silo
Evaporator pH — Trend
10.0 8.5 7.0 9.0 pH 13:30 14:00 14:30
pH value Alert threshold (9.0) Alert triggered
Analyse tab is available to Dealer role only. Switch role to explore this view.
Multi-sensor overlay
Select sensors from the list →
📈
No sensors selected.
Add one from the list to start.
Sensors
Alerts
2 active · 14 resolved
Active
Evaporator pH out of range
Evaporator Active 14:18 · 12 min ago
Washer dry bobber triggered
Washer Active 13:27 · 1h 3m ago
History
Evaporator fill valve timeout
Evaporator · Triggered 08:14
Resolved 08:31
Buffer silo too full
Buffer Silo · Yesterday 16:45
Resolved 16:52
Safety ventilator fault
Safety · Yesterday 09:01
Resolved 09:15
Washer empty valve stuck open
Washer · 2 days ago
Resolved
Settings
Last synced: 14 min ago
Read only
Settings are read-only for the Farmer role. Contact your dealer to make changes.
Buffer Silo
Fill time
How long the buffer silo fill valve stays open per fill cycle
120 s
Filter time
Duration of the microfilter cycle before the silo is released
45 s
Empty time
Maximum time allowed for the buffer silo to empty
180 s
Evaporator
Process time
Total duration of one evaporator batch cycle
3600 s
Fill time
Maximum time allowed to fill the evaporator before triggering an alert
90 s
Lag fill time
Extra wait time after the fill valve closes before the process continues
15 s
Leach pump on time
How long the leach pump runs per pulse during the evaporation phase
30 s
Leach pump off time
Rest interval between leach pump pulses
120 s
Leach pump pulses
Number of leach pump cycles per batch before requiring a counter reset
8
Start pH
Minimum pH required in the evaporator before the process will start
7.5 pH
Spray interval
How often the spray valve activates during evaporation
600 s
Blend interval
How often the blend cycle runs to homogenise the liquid
300 s
Empty time
Maximum time allowed for the evaporator to empty before triggering an alert
240 s
Lag empty time
Extra wait after the empty valve closes before the next state begins
20 s
Washer
Empty pH
Target pH level that indicates the washer is sufficiently empty
6.0 pH
Empty EC
Target conductivity level that confirms the washer liquid is spent
800 µS/cm
Max pH
Maximum permissible pH in the washer — exceeded values trigger acid dosing
9.0 pH
Acid pump pulses
Number of acid pump cycles per wash before requiring a counter reset
5
Acid pump on time
How long the acid pump runs per dosing pulse
20 s
Acid pump off time
Rest interval between acid pump pulses
90 s
Empty time
Maximum time allowed for the washer to empty before triggering an alert
300 s
Wait empty time
Settling delay after emptying before the washer accepts a new fill
60 s
Notifications
3 unread
🔴
Evaporator pH error
Evaporator pH exceeded configured threshold of 9.0 pH
Today 14:18
🔴
Washer dry bobber triggered
WasherDryBobber alert triggered in Washer subsystem
Today 13:27
🔵
Process started
Gazoo started a new batch process
Today 12:18
🔴
Evaporator fill valve timeout resolved
Alert resolved after 17 minutes
Today 08:31
🔵
Batch completed
Batch 47 completed successfully
Today 11:05
🔵
Gazoo is back online
Device reconnected after 4 minutes offline
Yesterday 16:42
🟡
Gazoo has not been seen for 15 min
Device may be offline — no heartbeat received
Yesterday 16:27